Bu kaydın yasal hükümlere uygun olmadığını düşünüyorsanız lütfen sayfa sonundaki Hata Bildir bağlantısını takip ederek bildirimde bulununuz. Kayıtlar ilgili üniversite yöneticileri tarafından eklenmektedir. Nadiren de olsa kayıtlarla ilgili hatalar oluşabilmektedir. MİTOS internet üzerindeki herhangi bir ödev sitesi değildir!

Modeling and Simulation of A Vacuum Distillation Unit in An Oil Refinery

Oluşturulma Tarihi: 12-06-2017

Niteleme Bilgileri

Tür: Tez

Alt Tür: Yüksek Lisans Tezi

Yayınlanma Durumu: Yayınlanmamış

Dosya Biçimi: PDF

Dil: İngilizce

Konu(lar): Kimya mühendisliği,

Yazar(lar): Al Muamri, Ali M. Ali Gerra (Yazar),

Emeği Geçen(ler): Kayı, Hakan (Araştırma Sorumlusu),

Anahtar Kelimeler

UniSim software, simulation, crude oil, vacuum distillation unit


Özet

In this thesis, we studied the modeling and simulation of a vacuum distillation unit (VDU). A distillation unit operating under vacuum pressure was designed to be fully used in Libyan refineries to make benefit from its residue instead of exporting it to other countries, and to extract more valuable products. The atmospheric residue has a very high boiling point (370 ºC). We need to find a way to decrease its boiling point, and then to separate it into its components easily and efficiently. It is known that when the pressure applied on a fluid decreases its boiling point decreases too. In the vacuum distillation column, the boiling point of the atmospheric residue is decreased by decreasing the pressure applied on the residue. The main products from the vacuum distillation unit are off gas, light vacuum gas oil (LVGO) and heavy vacuum gas oil (HVGO). In addition, a vacuum residue is produced.To be able to investigate the further distillation of the residue of the atmospheric distillation, a vacuum distillation unit was designed and simulated by Honeywell UniSim® Design v450 software, which is a very powerful program that helps us to create steady-state and dynamic models for plant design. At the end of the simulations, the liquid volume percent of the atmospheric residue was found to be 31.9%, while the liquid volume percent of vacuum residue was found to be 0.098%. Our simulations by using UniSim software indicated that the use of VDU significantly decrease the amount of the residue in the petroleum refinery.


İçindekiler



Açıklamalar



Haklar



Notlar



Kaynakça


Atıf Yapanlar

Gözat Sayfasına Dön

 

Sosyal Medya ve Araçlar

İstatistikler

  • Kayıt
    • Bu ay: 3
    • Toplam: 2444
  • Online
    • Ziyaretçi: 60
    • Üye: 0
    • Toplam: 60

Detaylı İstatistikler